FJZJP roots water jet vacuum unit set consists of roots pump as main pump including middle pump (which have two types, i.e. Anticorrosive or normal, while the former one is coated to get good corrosion resistance) and water jet pump as backing pump.
Full-plastic horizontal water jet vacuum unit set as backing pump to pump caustic gas. The ultimate vacuum of single-stage roots pump is 150Pa, of two-stage roots pump is 25Pa and of three-stage roots pump is 1 Pa.
Model Specification
Product Show
Model |
Pumping
Speed
(L/s) |
Ultimate
Pressure
(Pa) |
Pump Model |
Inlet
(mm) |
Main
Pump |
Power
(kw) |
ROR
(r/min) |
Line
Pump |
Power
(kw) |
ROR
(r/min) |
Backing
Pump |
Power
(kw) |
ROR
(r/min) |
FJZJP-70-180 |
70 |
150 |
ZJC-70 |
2.2 |
2900 |
-- |
-- |
-- |
JW-RPP-54-180 |
7.5 |
2900 |
50 |
FJZJP-150-280 |
150 |
150 |
ZJC-150 |
3 |
2900 |
-- |
-- |
-- |
JW-RPP-65-280 |
11 |
2900 |
65 |
FJZJP-150-360 |
150 |
150 |
ZJC-150 |
3 |
2900 |
-- |
-- |
-- |
JW-RPP-80-360 |
11-15 |
2900 |
80 |
FJZJP-150-500 |
150 |
150 |
ZJC-150 |
3 |
2900 |
-- |
-- |
-- |
JW-RPP-80-500 |
15 |
2900 |
80 |
FJZJP-300-500 |
300 |
150 |
ZJP-300 |
4 |
2900 |
-- |
-- |
-- |
JW-RPP-80-500 |
15 |
2900 |
80 |
FJZJP-70-30-180 |
70 |
25 |
ZJC-70 |
2.2 |
2900 |
ZJC-30 |
1.1 |
1450 |
JW-RPP-54-180 |
7.5 |
2900 |
50 |
FJZJP-150-70-280 |
150 |
25 |
ZJC-150 |
3 |
2900 |
ZJC-70 |
2.2 |
1450 |
JW-RPP-65-280 |
11 |
2900 |
65 |
FJZJP-150-70-360 |
150 |
25 |
ZJC-150 |
3 |
2900 |
ZJC-70 |
2.2 |
1450 |
JW-RPP-80-360 |
11-15 |
2900 |
80 |
FJZJP-300-150-500 |
300 |
25 |
ZJP-300 |
4 |
2900 |
ZJC-150 |
3 |
2900 |
JW-RPP-80-500 |
15 |
2900 |
80 |
Note:
① The performances in the table refers to air temperature at 20 ℃, atmospheric pressure at 1013.25hpa (760 mmHg), relative humidity of air at 70% and temperature of circulating water at 15℃.
② Tolerance of air pumping rate at ± 10%.
③ The readings of the degree of vacuum in the table refer to the pressure below standard atmospheric pressure. (1 mmHg = 1 Torr = 133.3 Pa, 0.1 Mpa = 750 mmHg)